Clinical interpretation and cutoff scores for manual ability measured by ABILHAND-RA questionnaire in rheumatoid arthritis: A receiver operating characteristic analysis study
Journal of Hand Therapy, 2026 (SCI-Expanded, Scopus)
- Yayın Türü: Makale / Tam Makale
- Basım Tarihi: 2026
- Doi Numarası: 10.1016/j.jht.2026.09.027
- Dergi Adı: Journal of Hand Therapy
- Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, CINAHL, EMBASE, MEDLINE, Health Research Premium Collection (ProQuest), Pharma Collection (ProQuest)
- Anahtar Kelimeler: Outcome assessment, Psychometrics, Rheumatoid arthritis, ROC curve, Sensitivity and specificity, Upper extremity
- Uşak Üniversitesi Adresli: Evet
Özet
Background: Although the ABILHAND-RA questionnaire demonstrates strong psychometric properties for assessing manual ability in patients with rheumatoid arthritis, cut-off scores have not yet been established, limiting its clinical interpretability and comparability across studies. Purpose: The purpose of this study was to establish cut-off scores for ABILHAND-RA questionnaire in rheumatoid arthritis. Study Design: Cross-sectional study. Methods: This study included 186 patients with rheumatoid arthritis (84.9% female, mean age 51.91 ± 11.01 years, mean disease duration 8.89 ± 7.57 years). ABILHAND-RA questionnaire, Disease Activity Score 28 (DAS28), grip strength, Health Assessment Questionnaire (HAQ), and Disabilities of Arm, Shoulder and Hand (DASH) were evaluated. Optimal cut-off scores for ABILHAND-RA were determined using receiver operating characteristic curve, sensitivity, and specificity analyses. Results: Patients were 84.9% female, mean age 51.9±11.0 years, with a mean disease duration 8.9±7.6 years). Due to extreme sample homogeneity (99.2% of patients with reduced grip strength), a severe ceiling/floor effect precluded its use as a clinical anchor. Consequently, optimal ABILHAND-RA cut-off points were determined based on HAQ, DASH, and DAS28 anchors. The ABILHAND-RA cut-off logits were 1.9 for HAQ; 1.8 and 1.5 for DASH; and 1.6, 1.6, and 1.5 for DAS28. Correspondingly, the raw scores were 43.5 for HAQ; 43.5 and 42.5 for DASH; and 34.5, 41.5, and 28.5 for DAS28. All estimated area under the curve (AUC) values were significant, indicating discriminatory performance better than chance. In particular, the thresholds calibrated against HAQ and DASH demonstrated good accuracy with AUC values above 0.80. The highest determined by the AUC was observed for the cut-off based on HAQ (AUC 0.89, 95%CI: 0.82-0.96). Conclusions: The ABILHAND-RA cut-off value of 1.914 logits is recommended, as the HAQ-based cut-off demonstrated the highest overall discriminatory accuracy.