Percutaneous retrieval of embolized Amplatzer septal occluder from pulmonary artery using a novel method


Candan Ö., Şahin M., Türkmen M.

Turk Kardiyoloji Dernegi Arsivi, vol.46, no.6, pp.501-503, 2018 (Scopus) identifier identifier identifier

  • Publication Type: Article / Article
  • Volume: 46 Issue: 6
  • Publication Date: 2018
  • Doi Number: 10.5543/tkda.2017.67523
  • Journal Name: Turk Kardiyoloji Dernegi Arsivi
  • Journal Indexes: Scopus, TR DİZİN (ULAKBİM)
  • Page Numbers: pp.501-503
  • Keywords: Atrial septal defect, Embolized device, Percutaneous retrieval
  • Uşak University Affiliated: No

Abstract

Summary– Percutaneous closure of atrial septal defects is accepted as a safe and effective treatment method. Device embolization is a rare, but potentially fatal complication. While embolized devices are typically removed surgically, in eligible cases, they can also be removed percutaneously at an experienced center. Presently described is the retrieval of an embolized device with a novel percutaneous technique.